These are low-frequency machines built around a toroidal transformer, with the solar charge controller in the same enclosure. That combination is why they tolerate what a light high-frequency hybrid cannot: motor start currents of three to seven times rated load, voltage sags down to 190 V, and 45 °C ambient without derating the output stage.
The trade-off is on the PV side. The controller works at battery voltage, so the maximum PV open-circuit voltage is 150 V on the 3–8 kVA models and 250 V on the 10 and 15 kVA units — not the 450–500 V of a high-frequency hybrid. Panel strings must be designed inside that window; our technical note on PV input voltage explains how.
Typical applications
- Residential off-grid systems
- Small shops and clinics
- Guest houses and rental properties
- Light commercial with motor loads
Models
- WS-3024
- WS-5048
- WS-8048
- WS-10KVA
- WS-15KVA
- WS-1000 · 2000 · 3000 · 5000 · 8000 (without controller)
Inverter certification: none held for this range. Test reports are provided with quotations on request.